Honeywell AutoRae2
Keep your instrument operating correctly and handle your compliance with the test stations, gases and accessories.
Simplify bump testing and calibration of your RAE Systems gas monitors with the AutoRAE 2. Versatile and modular, it can be deployed as a single, stand-alone unit to calibrate one instrument at a time, or networked to support up to 10 units at once and calibrate for up to five distinct gases. One-touch bump testing and single-button operation for calibration make it easy to use. Upgradeable firmware protects your investment and ensures that it’s always up-to-date, while the standard SD card for storage ensures your data is always at your fingertips.
Features and Benefits:
- Easy, one-touch bump testing, calibration, charging, and records management
- Supports a wide variety of gases, including exotics
- Optimized for field use–does not require a computer to operate
- Can be used on a bench top or mounted on the wall
- Deployable as a standalone cradle or a controller-based system with up to 10 cradles
- Networking capability
- Data storage on a standard SD card
- Instrument supported:ToxiRAE Pro, ToxiRAE Pro LEL, ToxiRAE Pro PID, ToxiRAE Pro CO2: QRAE 3: MicroRAE, MulitRAE Lite (pumped version only), MulitRAE, MultiRAE Pro, MultiRAE Benzene, MiniRAE Lite, MiniRAE 3000, UltraRAE 3000 and ppbRAE3000
Controller Includes:
- Terminal Adapter
- Power Supply
- End Cap
AutoRAE 2 Cradles include everything required to run in standalone mode or as part of a controller-based system w/multiple cradles. No gas, regulators or external tubing.
Accessories:
Calibration Gas
Regulators
Tubing
Ethernet Cable
PC Communications CAble (USB 2.0)
External Water trap filter 25mm w/o adapter
Teflon tubing for reactive gases
Active Carbon Filter
Warranty: 2-year limited warranty
Application:
- CBRNE
- Clandestine Labs
- Confined Space Entry
- Decontamination
- Emergency Response
- Environmental Cleanups/ Remediation
- Exploration
- Fire Overhaul
- Fracking
- Hazmat Response
- Indoor Air Quality
- Leak Detection
- Plant Shutdown & Turn-Around
- Residential Calls
- Urban Search & Rescue
- Venue Protection
- Worker Exposure
Learning Center:
Technical Note Gas Sequences for Calibration and Calibration Check Testing:Technical Note 203 Gas Sequences for Calibration and Calibration Check Testing of the MultiRAE Instrument Family
Connect With An Expert Today
Or We’ll Get Back to You...
Paul Blair
(Eastern Canada)
Gishan Perera
(Quebec)
Melodie Henderson
(Western Canada)
Todd Cranston
(Atlantic Canada)
Brice Brown
(International)
226-271-2211



